EICR Rules for Landlords in England: How Often, Cost and Fines
If you rent out a home in England, you must have the electrics checked regularly and keep an up-to-date Electrical Installation Condition Report (EICR). This guide explains the rules in plain English, so you know exactly what to do and when.
- You need an EICR at least every 5 years, or sooner if the report says so.
- Give tenants a copy within 28 days of the inspection.
- Fix any urgent problems within 28 days (or sooner if the report says so).
- Councils can fine landlords up to £30,000 for breaking the rules.
What is an EICR?
An EICR is a report on the safety of the fixed electrical installation in your property: the wiring, sockets, light fittings, consumer unit (fuse box) and so on. A qualified electrician inspects and tests everything, then gives the installation an overall result of "satisfactory" or "unsatisfactory".
These rules come from the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, which have applied to all private tenancies in England since April 2021.
How often do landlords need an EICR?
At least every 5 years. But if the electrician writes a shorter date on the report, for example 3 years because the wiring is old, you must follow that shorter date.
You don't automatically need a new EICR for each new tenant, as long as the current one is still in date.
Who can carry out an EICR?
It must be a qualified and competent person. The simplest way to be sure is to use an electrician registered with a competent person scheme, such as NICEIC or NAPIT. You can search for a registered electrician on the Electrical Competent Person register.
Who needs a copy, and when?
| Who | Deadline |
|---|---|
| Existing tenants | Within 28 days of the inspection |
| New tenants | Before they move in |
| Prospective tenants who ask for it | Within 28 days of their request |
| The local council, if it asks | Within 7 days of the request |
| The next electrician | Keep a copy to give them at the next inspection |
What do the codes on the report mean?
The electrician uses codes to show any problems they find:
| Code | Meaning | Do you need to act? |
|---|---|---|
| C1 | Danger present, risk of injury | Yes, urgently. The electrician may make it safe on the spot. |
| C2 | Potentially dangerous | Yes, within 28 days or sooner if stated |
| FI | Further investigation needed | Yes, within 28 days or sooner if stated |
| C3 | Improvement recommended | No, it's advice only, but worth considering |
If the report has any C1, C2 or FI codes, the overall result is "unsatisfactory" and you must act.
What if the report is "unsatisfactory"?
- Get the remedial work (or further investigation) done within 28 days, or sooner if the report says so.
- Get written confirmation from the electrician that the work is done and the installation now meets the standard.
- Send that confirmation, plus a copy of the original report, to your tenants and the local council within 28 days of the work being finished.
How much does an EICR cost?
Prices vary by area and property size. As a rough guide, an EICR for a typical flat or small house commonly costs somewhere around £100 to £300, with larger properties and HMOs costing more. Any repair work is charged separately.
Tip: get 2–3 quotes, and check whether the price includes the written report. Some landlords book the EICR and the annual gas safety check at the same time to reduce disruption for tenants.
What are the fines for not having an EICR?
If a landlord breaks the rules, the local council can:
- Issue a fine of up to £30,000 (a civil penalty).
- Serve a notice requiring you to do the work.
- Arrange the work themselves and recover the cost from you.
Beyond fines, electrical faults are a real safety risk to your tenants and your property, so it's worth staying on top of.
Common questions
Do I need PAT testing for appliances I provide?
PAT testing isn't required by these regulations, but it's good practice to make sure any appliances you supply are safe. The EICR covers the fixed wiring, not plug-in appliances.
Does this apply if I have a lodger?
Lodgers who live with you (where you share the home) are generally not covered by these regulations. They mainly apply to private tenancies where you don't live in the property.
My EICR says 10 years. Is that OK?
No. For rented homes in England, the maximum is 5 years, even if the report suggests longer. Some older reports written for owner-occupied homes show 10 years.
What about Scotland and Wales?
Both also require regular electrical checks for rented homes, but the rules are different. Check the Scottish or Welsh government's guidance for details.
How to never miss your EICR
- Note the "next inspection" date on your current report.
- Set a reminder 2 months before, as electricians can get booked up.
- Keep a copy of every report and completion certificate in one place.
See our full UK landlord certificate checklist for gas safety, EPC, deposits and more.
Never miss an EICR again
Remindlord will email you before your EICR, gas safety and EPC are due, with all your certificates in one place. Join the waitlist and get 50% off for life.
Join the waitlistThis guide is general information for landlords in England and isn't legal advice. Rules can change. Always check the official government guidance or a qualified professional for your situation.